- 品牌/商標(biāo):西門子
- 企業(yè)類型:貿(mào)易商
- 新舊程度:全新
- 原產(chǎn)地:德國
Overview
- 功能強(qiáng)大的 SIMATIC S7-400 CPU
- 可用在高性能范圍中復(fù)雜的裝置
- 有 2 個 IF 模塊插槽
Area of application
The CPU 417-4 is the most powerful SIMATIC S7-400 CPU. The integral PROFIBUS DP interfaces permit direct connection to the PROFIBUS DP fieldbus as master or slave.
Two further DP master systems can be connected via the IF 964-DP interface submodules.
Note :
Only the interface module 6ES7 964-2AA04-0AB0 can be used.
Design
The CPU 417-4 has:
- Powerful processor:
The CPU achieves instruction execution times as low as 0.018 μs per binary instruction. - 30 MB RAM (of which 15 MB each for program and data);
fast RAM for parts of the user program relevant to execution. - Flexible expansion:
Up to 262144 digital and 16384 analog inputs/outputs. - Multi-point interface MPI:
With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPU can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
Note:
If the PROFIBUS DP interface and MPI interface are operated simultaneously, it is only possible to connect the following bus connector to the MPI interface:- With socket: 6ES7 972-0BB41-0XA0
- Without socket: 6ES7 972-0BA41-0XA0
- Mode selector switch:
Designed as toggle switch. - Diagnostics buffer:
The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes (extendable). - Real-time clock:
The date and time are appended to diagnostic messages of the CPU. - Memory card:
For expansion of the integrated load memory. The information in the load memory comprises S7-400 parameterization data in addition to the program and therefore requires twice as much memory space. The result is:- The integral load memory is not sufficient for large programs, therefore a memory card is frequently required.
RAM and FEPROM cards (FEPROM for retentive storage) are available
- The integral load memory is not sufficient for large programs, therefore a memory card is frequently required.
- PROFIBUS DP interface:
The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing, and programming).
Mixed configuration: SIMATIC S5 with SIMATIC S7 as PROFIBUS master to EN 50170.
Note:
If the PROFIBUS DP and MPI interface are operated simultaneously, it is only possible to connect the following bus connectors to the MPI interface:- With socket: 6ES7 972-0BB41-0XA0
- Without socket: 6ES7 972-0BA41-0XA0
- Two additional slots:
Two additional PROFIBUS DP master systems can be connected via IF 964-DP interface modules.
Functions
- Block protection:
a password concept also protects the user program from unauthorized access - Integrated HMI services:
The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. - Integrated communication functions:
- PG/OP communication
- Global data communication
- S7 standard communication
- S7 communication
Configurable Attributes
The STEP 7 tool "Hardware configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.
- Multipoint interface MPI:
- Definition of node addresses
- Startup/cycle behavior
- Stipulation of the maximum cycle time and communication load
- Address allocation:
Addressing of I/O modules - Retentive area:
Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories - Size of the process image, local data
- Length of the diagnostics buffer
- Protection level:
Definition of access authorizations to program and data - System diagnostics:
Definition of the handling and scope of diagnostics messages - Timed interrupts:
Setting of periods - Configuring
Reporting functions
- Status and fault indicators:
LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc. - Test functions:
The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. - Information functions:
The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.
Technical Specifications
| 6ES7 417-4XT05-0AB0 |
| CPU 417-4 |
一般信息 |
|
硬件產(chǎn)品型號 | 04 |
固件型號 | V5.3 |
工程組態(tài) |
|
| STEP 7 V5.3 SP2 或更高,帶硬件更新 |
CiR - 在 RUN 模式下組態(tài) |
|
CiR 同步時間,基本負(fù)載 | 60 ms |
CiR 同步時間,每個 I/O 從站的時間 | 7 μs |
電源電壓 |
|
24 V DC | ×;電源通過系統(tǒng)電源提供 |
輸入電流 |
|
從背板總線 5 V DC, | 1.8 A |
從接口 5 V DC, | 90 mA;在每個 DP 接口處 |
功耗 |
|
功耗,典型值 | 7.5 W |
功耗, | 8 W |
內(nèi)存 |
|
工作存儲器 |
|
| 30 Mbyte |
| 15 Mbyte |
| 15 Mbyte |
| X |
裝載存儲器 |
|
| √;帶存儲卡(FLASH) |
| 64 Mbyte |
| 1 Mbyte |
| √;帶存儲器卡 (RAM) |
| 64 Mbyte |
后備 |
|
| √ |
| √;所有數(shù)據(jù) |
| X |
CPU 處理時間 |
|
位操作,典型 | 18 ns |
字操作,典型 | 18 ns |
定點(diǎn)數(shù)運(yùn)算,典型 | 18 ns |
浮點(diǎn)數(shù)運(yùn)算,典型 | 54 ns |
CPU 塊 |
|
DB |
|
| 16,000;編號范圍:1 到 16000 |
| 64 kbyte |
FB |
|
| 8,000;編號范圍:0 到 7999 |
| 64 kbyte |
FC |
|
| 8,000;編號范圍:0 到 7999 |
| 64 kbyte |
OB |
|
| 64 kbyte |
嵌套深度 |
|
| 24 |
| 2 |
計數(shù)器、定時器及其保持性 |
|
S7 計數(shù)器 |
|
| 2 048 |
|
|
| √ |
| 0 |
| 2 047 |
| Z0 ~ Z7 |
|
|
| 0 |
| 999 |
IEC 計數(shù)器 |
|
| √ |
| SFB |
| 不限(只取決于 RAM 容量) |
S7 定時器 |
|
| 2 048 |
|
|
| √ |
| 0 |
| 2 047 |
| 無保持定時器 |
|
|
| 10 ms |
| 9,990 s |
IEC 定時器 |
|
| √ |
| SFB |
| 不限(只取決于 RAM 容量) |
數(shù)據(jù)區(qū)及其保持性 |
|
保持?jǐn)?shù)據(jù)區(qū)域,總共 | 總工作存儲器和裝入存儲器(帶有備用電池) |
標(biāo)志 |
|
| 16 KB;位存儲器地址區(qū)域大小 |
| √ |
| MB 0 - MB 15 |
| 8; (1個存儲字節(jié)) |
局部數(shù)據(jù) |
|
| 64 kbyte |
| 32 kbyte |
地址區(qū) |
|
I/O 地址區(qū) |
|
| 16 kbyte |
| 16 kbyte |
|
|
| 2 kbyte |
| 2 kbyte |
| 8 kbyte |
| 8 kbyte |
過程映像 |
|
| 16 kbyte |
| 16 kbyte |
| 1,024 字節(jié) |
| 1,024 字節(jié) |
| 244 字節(jié) |
| √ |
子過程映像 |
|
| 15 |
數(shù)字量通道 |
|
| 131 072 |
| 131 072 |
| 131 072 |
| 131 072 |
模擬量通道 |
|
| 8 192 |
| 8 192 |
| 8 192 |
| 8 192 |
硬件配置 |
|
擴(kuò)展設(shè)備, | 21 |
多CPU運(yùn)行 | √;多 4 個 CPU(帶 UR1 或 UR2) |
接口模塊 |
|
| 6 |
| 6 |
| 4; IM 463-2 |
DP 主站的數(shù)量 |
|
| 2 |
| 4 |
| 10;CP 443-5 擴(kuò)展 |
| ×;IM 467 不適用于 CP 443-5 Ext.及 CP443-1 EX4x、EX20、GX20(PNIO 模式) |
| 2 |
| 6 |
IO 控制器的數(shù)量 |
|
| 0 |
| 4;不與 CP443-1 EX40 及 CP443-1 EX 41/EX20/GX20 混合操作,中央控制器中多為 4 個 |
可運(yùn)行的 FM 和 CP 數(shù)量(推薦) |
|
| 受插槽數(shù)和接口數(shù)的限制 |
| CP 440:受插槽數(shù)限制;CP 441:受連接數(shù)限制 |
| 14;其中多有 10 個 CP 或 IM 作為 DP 主站,多有 4 個 PN 控制器 |
時間 |
|
時鐘 |
|
| √ |
| √ |
| 1 ms |
| 1.7s;掉電 |
| 8.6s;通電 |
運(yùn)行小時計數(shù)器 |
|
| 16 |
| 0 到 15 |
| SFC 2, 3 和 4:0 至 32767 小時 SFC 101:0 - 2^31 - 1 小時 |
| 1 小時 |
| √ |
時鐘同步 |
|
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| X;通過 CP |
| √ |
數(shù)字量輸出 |
|
集成通道 (DO) | 0 |
模擬量輸入 |
|
集成通道(AI) | 0 |
接口 |
|
接口 | 1 x MPI/PROFIBUS DP,1 x PROFIBUS DP,2 x PROFIBUS DP(可以是插入式) |
USB 接口數(shù)量 | 0 |
第 1 個接口 |
|
接口類型 | 集成 |
物理 | RS 485 / PROFIBUS + MPI |
隔離 | √ |
接口電源 (15-30 VDC), | 150 mA |
連接源數(shù)量 | MPI:44, DP: 32 |
功能性 |
|
| √ |
| √ |
| √ |
MPI |
|
| 44;如線路使用診斷中繼器,則線路的連接資源數(shù)減 1 |
|
|
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 12 Mbit/s |
DP 主站 |
|
| 32;如線路使用診斷中繼器,則線路的連接資源數(shù)減 1 |
|
|
| √ |
| X |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 12 Mbit/s |
| 32 |
|
|
| 2 kbyte |
| 2 kbyte |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 244 字節(jié) |
| 244 |
| 128 字節(jié) |
DP 從站 |
|
| 32 |
|
|
| √;帶有有源接口 |
| √;帶有有源接口 |
| X |
| X |
| √ |
| √ |
| √ |
| X |
| X |
| |
| 12 Mbit/s |
| X |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 32;虛擬槽 |
| 32 字節(jié) |
| 32 字節(jié) |
第 2 個接口 |
|
接口類型 | 集成 |
物理 | RS 485 / PROFIBUS |
隔離 | √ |
接口電源 (15-30 VDC), | 150 mA |
連接源數(shù)量 | 32 |
功能性 |
|
| √ |
| √ |
DP 主站 |
|
| 32 |
|
|
| √ |
| X |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 12 Mbit/s |
| 125 |
|
|
| 8 kbyte |
| 8 kbyte |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 244 字節(jié) |
| 244 |
| 128 字節(jié) |
DP 從站 |
|
| 32 |
| https://support.automation.siemens.com/WW/view/de/113652 |
| 12 Mbit/s |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 32 |
| 32 字節(jié) |
| 32 字節(jié) |
第 3 接口 |
|
接口類型 | 插入式接口模塊 (IF),技術(shù)數(shù)據(jù)與第 2 個接口相同 |
插入式接口模塊 | IF 964-DP (MLFB:6ES7964-2AA04-0AB0) |
物理 | RS 485 / PROFIBUS |
隔離 | √ |
接口電源 (15-30 VDC), | 150 mA |
自動檢測傳輸速率 | X |
連接源數(shù)量 | 32 |
功能性 |
|
| X |
| √ |
| √ |
DP 主站 |
|
| 32 |
|
|
| √ |
| X |
| X |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 12 Mbit/s |
| 125 |
|
|
| 8 kbyte |
| 8 kbyte |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 244 字節(jié) |
| 244 |
| 128 字節(jié) |
DP 從站 |
|
| 32 |
|
|
| √ |
| √;帶有有源接口 |
| X |
| X |
| √ |
| √ |
| √ |
| X |
| X |
| https://support.automation.siemens.com/WW/view/de/113652 |
| 12 Mbit/s |
| X |
|
|
| 244 字節(jié) |
| 244 字節(jié) |
| 32 |
| 32 字節(jié) |
| 32 字節(jié) |
第 4 接口 |
|
接口類型 | 插入式接口模塊 (IF),技術(shù)數(shù)據(jù)與第 2 個接口相同 |
插入式接口模塊 | IF 964-DP (MLFB:6ES7964-2AA04-0AB0) |
等時同步模式 |
|
同步操作(一直同步至端子) | √;僅 PROFIBUS |
同步模式下 DP 主站的數(shù)量 | 4 |
每個等時從站的用戶數(shù)據(jù), | 244 字節(jié) |
等距離 | √ |
短時鐘脈沖 | 1ms;不使用 SFC 126、127 時 0.5ms |
循環(huán) | 32 ms |
通信功能 |
|
編程器/OP 通信 | √ |
| 63 |
| 63;使用 alarm_S 和 alarm_D 時 |
數(shù)據(jù)記錄路由 | √ |
全局?jǐn)?shù)據(jù)通信 |
|
| √ |
| 16 |
| 32 |
| 54 字節(jié) |
| 1;可變 |
S7 基本通信 |
|
| √ |
| 76 字節(jié) |
| 1;可變 |
S7 通信 |
|
| √ |
| √ |
| √ |
| 64 kbyte |
| 462 字節(jié);1 個變量 |
S5 可兼容通信 |
|
| √;通過 FC AG_SEND 和 AG_RECV,通過多 10 個 CP 443-1 或 443-5 |
| 8 kbyte |
| 240 字節(jié) |
| 64/64 |
標(biāo)準(zhǔn)通信(FMS) |
|
| √;通過 CP 和可加載的功能塊 |
開放式 IE 通信 |
|
| 通過 CP 443-1 和可調(diào)用的 FB |
| 1452 字節(jié),通過 CP 443-1 Adv. |
Web 服務(wù)器 |
|
| X |
連接數(shù)量 |
|
| 64 |
S7 報文功能 |
|
報文功能可以登錄站的數(shù)量,多 | 63;多 63 個帶有 ALARM_S 和 ALARM_D (OP);多 12 個帶有 ALARM_8 和 ALARM_P(如 WinCC) |
與符號相關(guān)的報文 | √ |
SCAN 程序 | √ |
報文數(shù)量 |
|
| 1 024 |
與塊相關(guān)的報文 | √ |
過程診斷報文 | √ |
可同時激活的 Alarm-S 塊,多 | 1 000;同時激活 alarm_S/SQ 塊或 alarm_D/DQ 塊 |
8 個報警功能塊 | √ |
| 10 000 |
| 1 200 |
過程控制報文 | √ |
調(diào)試功能 |
|
狀態(tài)/控制 |
|
| √;多達(dá) 16 個變量表 |
| I/O、存儲位、數(shù)據(jù)庫、分布式 I/O、定時器、計數(shù)器 |
| 70;狀態(tài)/控制 |
強(qiáng)制 |
|
| √ |
| 輸入、輸出、位存儲器、外設(shè)輸入,外設(shè)輸出 |
| 512 |
狀態(tài)塊 | √;多 2 個,同時 |
單步運(yùn)行 | √ |
斷點(diǎn)數(shù)量 | 4 |
診斷緩沖區(qū) |
|
| √ |
| 3 200 |
| √ |
| 120 |
組態(tài) |
|
編程 |
|
|
|
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 見“指令表” |
| 7 |
專門知識保護(hù) |
|
| √ |
外形尺寸 |
|
寬 | 50 mm |
高度 | 290 mm |
深 | 219 mm |
所需插槽 | 2 |
重量 |
|
重量,約 | 0.9 kg |